Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX and UL.
Low cost of ownership
Flexible installation options
Wide range of sensors
Rugged and reliable
Type 1 | Type 2 | Type 3 | Type 4 | Type 5 | Type 6 | Xsafe | ||
Size | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | |||||
Weight | Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) | Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) | 1.5 kg (3.3lbs) | Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) | 1kg (2.2lbs) | |||
Enclosure material | ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S | Aluminium or 316 Stainless Steel | Aluminium | Aluminium or 316 Stainless Steel | Aluminium | |||
Ingress protection | IP65 | IP54 | IP65 | |||||
Cable entries | 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side | |||||||
Terminations | 0.5 to 2.5mm2 | |||||||
Sensor type | Electrochemical | Catalytic bead | 316 S/S sensor housing with catalytic beads | Catalytic bead | Thermal conductivity | Catalytic bead | ||
Operating temperature | -20 to +50 °C (-4 to 122 °F) (sensor dependant) |
-20 to +50°C (-4 to 122°F) | -40 to +80°C (-40 to 176°F) |
-20 to +150°C (-4 to 302°F) | -40 to +55°C (-40 to 131°F) | +10 to +55°C (50 to 301°F) | mV: -40 to +80oC (-40 to 176oF) mA: -40 to +55oC (-40 to 131oF |
|
Humidity | 10 to 95% RH non-condensing | 0-99% RH non-condensing | 0-90% RH | 0-99% RH | ||||
Repeatability Zero drift | <2% FSD (Typical)<2% FSD per Month (Typical) | |||||||
Response time | T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) | T90 <15s (Typical) | ||||||
Operating voltage | 8-30V dc | 2.0V dc +/- 0.1V (Typical) | 10-30V dc | mA: 10- 30V dc mV:2.0Vdc | ||||
Power requirements | 24mA maximum | 300mA (Typical) | 50mA at 24V dc 1.2W | MA:50mA at 24V dc 1.2W mV: 300mA (Typical) | ||||
Electrical output | 2- wire 4-20mA (current sink) | 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 | 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 | 3- wire 4-20mA (current sink or source) | mA: 3- wire 4-20mA (current sink or source) mV: 3- wire mV bridge Typical signal: 12-15mV/ %LEL CH4 |
|||
Approvals | ATEX: II 1 G Exia IIC T4 Ga (Tamb -40 to +55°C) UL/cUL: Class I, Div. 1 Groups A, B, C, D IECEx |
ATEX: II 2GD Exd IIC T6 Gb (Tamb -40 to +50°C) UL: Class I, Div. 1 Groups B, C, D IECEx |
ATEX: II 2 GD Exd IIC T4 Gb (Tamb -40 to +80°C) Exd IIC T6 Gb (Tamb -40 to +50°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx |
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) | ATEX/IECEx: II 2 GD
Ex db IIC T4 Gb – Ex tb IIIC T110˚C Db (Tamb -40 to +80˚C) Ex db IIC T6 Gb – Ex tb IIIC T80˚C Db (Tamb -40 to +50˚C) UL : Class I, Div 1 Groups B, C, D |
|||
EMC compliance | EN 50270 FCC Part 15 ICES- 003 |
*3/4 ” cable entry only available on aluminium juntion boxes.
Gas options |
Acetylene (C2H2), Argon (Ar), Arsine (AsH3), Bromine (BR2), Butane (C4H10), Carbon Dioxide (CO2), Diborane (B2H6), Ethane (C2H6), Ethylene (C2H4), Ethylene oxide (C2H4O), Germane (GeH4), Helium (He), LPG, Pentane (C5H12), Petrol vapour, Propane (C3H6), Silane (SiH4), Vinyl chloride (VCM) (CH2 = CHCI, Volatile organics (VO), Ammonia (NH3), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Fluorine (F2), Hydrogen (H2), Hydrogen chloride (HCL), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Methane (CH4), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosgene (COCL2), Phosphine (PH3), Sulphur dioxide (SO2) |
---|---|
Number of gases |
1 |
Weight |
Type 1 – Nylon: 0.5kg (1.1 lbs) Alloy: 1kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs), Type 2, 3, 5, 6 – Aluminium: 1kg (2.2 lbs) Stainless steel: 3.1kg (6.8lbs), Type 4 – 1.5kg (3.3 lbs), Xsafe – 1kg (2.2 lbs) |